1‑minute website monitoring and custom check intervals
Uptimia sets the check interval per monitor, with uptime checks from every 30 seconds to once a day. On 30‑second checks an outage goes unseen for 30 seconds at most, against up to 5 minutes on a 5‑minute interval.
Monitoring Logs
every 30 s · one location per check
Tokyo14:32:18—Down
London14:32:16—Down
New York14:32:14—Down
Frankfurt14:32:11—Down
Amsterdam14:31:41382 msUp
New York14:31:11371 msUp
Frankfurt14:30:41358 msUpHTTP Response — Last Check
Amsterdam · 14:31:41Frankfurt · 14:32:11Response Time
avg 390 ms · last 7 daysShort outages slip between slow checks
If an outage starts and ends between two checks, you get no alert and the monitor's history shows nothing.
On the 30‑second monitor, the outage is on record 20 seconds after it began, whatever alert delay you set. Both checks on the 15‑minute monitor answered up, so its history has no trace of the outage. Choose each interval by what an unseen minute costs on that page. For a checkout that takes orders, that usually means every 30 seconds.
Price a blind minute with the downtime cost calculator →What sets the time to alert
Only the wait for the next check depends on the interval. Confirmation and the alert delay filter out blips, so a faster interval does not add alerts for failures that clear by themselves.
-
Wait for the next check
Set by the interval. The wait averages half an interval and can last a whole one. Moving a monitor from 5 minutes to 30 seconds cuts the longest wait by 4 minutes 30 seconds.
Set per monitor -
Confirmation round from other locations
Checked again from elsewhere. The moment a check fails, backup checks from other locations are queued, so a bad route at one checkpoint does not reach you as an alert. You choose 1, 2 or 3 backup checks, and each one must also fail.
Your choice, 1 to 3 -
Alert delay you set
A hold from instant to 30 minutes. An outage that ends inside the delay pages nobody, though the incident still goes on record with its duration. Pair a fast interval with a short delay to find outages early without an alert for every blip.
Yours, 0 to 30 min
Where the interval shows up
You see the pace you pick in the editor, in the summary beside it and in the spacing between rows in the check log.
Check frequency slider
One slider runs from every 30 seconds up to every 24 hours, and the sentence under it reads the setting back before you save. The alert-delay slider sits right below it.
Plain-language summary before you save
Beside the form, a summary describes the monitor in full sentences: its pace, confirmation, locations and who gets alerted. Click a line to jump to the setting behind it.
Check log rows spaced by the interval
Every check lands as a row with its time, result, location and response time. The Gap column here shows the spacing between rows, which is your interval. Open a row for the location, the URL and any error.
Set the check interval on each monitor,from every 30 seconds to once a day.
Checks run from 171+ locations, and website failures are confirmed before you're alerted.
Pick the interval by downtime cost
Each monitor has its own interval, so you decide page by page. Put the fastest checks on the pages that take money or sign people in, and let the rest run slower.
- Revenue paths every 30 seconds. Checkout, sign-in and the API, where an unseen minute is lost orders and support tickets.
- Brochure pages every 5 minutes. A marketing site or a blog loses little in a few blind minutes.
- Change it at any time. Tighten the checkout for a launch week and relax it afterwards. The next check uses the new pace.
Alerts confirmed before anyone is paged
Check frequency, outage confirmation and alert delay are set on each monitor. A 30‑second interval finds an outage early. If the failure clears before backup checks confirm it or before the delay runs out, no alert is sent.
Check frequency per monitor
Set each monitor anywhere from every 30 seconds to once a day. A line under the slider repeats the setting in plain words before you save, and the next check runs at the new pace.
Outage confirmation from backup checks
One checkpoint seeing an error proves little, since the fault may sit on that checkpoint's route. A website failure is confirmed by backup checks from other checkpoints before you're paged, at every interval.
Alert delay for flapping endpoints
Hold the alert back for up to 30 minutes, or send it instantly. With a 30‑second interval and a 2‑minute delay, the outage is still found and recorded early. A cache rebuild that clears in 90 seconds pages nobody.
- You choose how many must agree. 1, 2 or 3 backup checks, at every interval.
- What each alert includes. Failing location, error, response, headers and a traceroute.
- One passing check closes the incident. Everyone alerted gets the all-clear with the outage duration.
Check intervals for each monitor type
Uptime, speed and server monitors go down to 30 seconds. SSL and domain monitors have slower floors, since a certificate or a domain registration changes only when you renew it.
Checks spread across your locations
Each check runs from one of the locations you select, out of 171+ in 70+ countries, so consecutive checks usually come from different cities. Every row in the check log shows its checkpoint location.
- One request per check. At 30 seconds that is 2,880 requests a day, each from one location.
- Same pace at all hours. The interval does not slow down at night or over a weekend, so an outage at 3 a.m. on a Sunday waits no longer for its first check.
- Checks pause only for maintenance. They stop for the window you schedule and pick up again when it ends.
Also included
Heartbeats & cron
For backups and queue workers the job pings Uptimia on its own schedule, an interval from 30 seconds to 90 days or a cron expression, and a missed ping opens an incident once the grace period runs out.
Maintenance windows
Schedule planned work and the monitor's checks pause for the window, so a deploy under 30‑second checks pages nobody.
Recovery notices
One passing check closes the incident, and the all-clear tells everyone who was alerted how long it lasted.
Scheduled reports
Uptime and average response time for every monitor, sent daily, weekly, monthly, quarterly or yearly as PDF, HTML or CSV.
Bulk create at one interval
Paste one URL per line, or url,name pairs, and every new monitor gets the same check frequency, alert delay and confirmation.
One dashboard for everything
Uptime checks every 30 seconds, daily SSL checks, weekly domain refreshes and a nightly heartbeat can all run in the same account and use the same alerting setup.
Example monitors and their settings
Each example lists the monitor settings that fit the case and what Uptimia shows while it happens, from a checkout checked every 30 seconds to a nightly backup that never reports.
Checkout checked every 30 seconds
The payment page stops answering between two checks. The next check runs from Dallas 20 seconds later and is the first to fail. Backup checks from 3 other locations are queued the moment it does.
What the monitor shows and what happens →
- On the monitor
- A row lands in the check log every 30 seconds. The Down row is the first check after the outage began, and the incident lists the backup checks that confirmed it.
- What happens
- With no alert delay, the alert goes out as soon as the backup checks agree, naming the failing location and the error. The recovery notice carries the outage duration.
A 20‑second blip that paged nobody
A search endpoint drops requests for 20 seconds while its cache rebuilds. The 30‑second check lands inside that window and fails. Backup checks from other locations follow, and by the time they run, the endpoint is answering again.
What the monitor shows and what happens →
- On the monitor
- The monitor stays Up and no incident is recorded. One backup check that gets a reply is enough to clear a failure that was never confirmed.
- What happens
- Nobody is paged. Had the backup checks found the endpoint still down, the incident would open and, with no alert delay set, the alert would go out right away.
A failed automatic certificate renewal
The automated renewal fails and nobody notices, because the old certificate keeps working. A certificate changes only when you deploy one, so one check a day is enough to watch the date.
What the monitor shows and what happens →
- On the monitor
- The first daily check that sees 7 days left raises the expiry alert. A 10‑minute pace would raise it at most a day sooner.
- What happens
- The alert reaches the monitor's recipients with a week to fix the renewal. Once you renew, the next daily check reads the new expiry date.
The nightly backup that never reported
The backup job runs every night and pings Uptimia when it finishes. One night the disk fills and the job dies before the ping. An uptime check would see a healthy site, because nothing it can reach has changed.
What the monitor shows and what happens →
- On the monitor
- The schedule runs in your account's timezone. Monday's and Tuesday's pings came in late but inside the grace window. On Wednesday the window runs out with no ping, and the run is marked missed.
- What happens
- An incident opens when the grace period runs out, and you're alerted as for any outage. If the job catches its own error, it can send a failure signal, which opens the incident without waiting out the grace period.
Put 30‑second checks on your checkoutand slower ones on the rest.
Choose the backup checks and the alert delay for each monitor as you add it.
How monitoring intervals work
Uptimia checks each monitor on the interval you set, each check from one of 171+ locations, with uptime checks anywhere from every 30 seconds to once a day. When an uptime check fails, backup checks from other locations confirm it before the alert goes out, and one passing check closes the incident with the outage duration.
01What check interval should I use?+
02How fast will I know my site is down?+
03Which plans include 30-second checks?+
04Will frequent checks put load on my site?+
05How do I change the interval on an existing monitor?+
06Can I be alerted only if the failure lasts?+
07Does a faster interval cause more false alarms?+
08How many checks a month does each interval make?+
09Why can SSL, domain and virus monitors not run every 30 seconds?+
10What is the fastest interval for API and transaction monitors?+
11Does the server agent have an interval?+
12What about monitoring cron jobs on a schedule?+
13Do DNS and blacklist monitors have an interval?+
Give every monitor its own interval.
Website failures are confirmed from other locations before anyone is paged.